Slimline 100 Range: 230v and 12v

pdf Download & print PDF page
Slimline 100 Range: 230v and 12v

The SLIMLINE range of 100mm (4") fans comprises quiet, efficient, axial flow fans for wall or ceiling mounting. Designed for easy installation, attractively styled in high gloss ABS thermoplastics for modern appearance and ease of cleaning and incorporating the latest technology and design.

The SLIMLINE 100 series is ideally suited for domestic applications including bathrooms, toilets and shower areas.

The range is available in 230v and 12v Low Voltage.

The fans are extremely aesthetically pleasing as they have a 12mm profile.

Fans can be wall or ceiling mounted
British made
Designed to exceed the 2006 Building Regulations on Ventilation (F1)
Tested to comply with HD280/BS3456 Part 102:342 1988
Aesthetically pleasing
2 year no quibble guarantee
CE Mark

Technical Data

230v models

Catalogue No.Type
SL100Standard model - for remote switching.
SL100SAs above supplied with integral pull switch.
SL100TTimer model - with integral over-run timer (15 mins).
SL100HTSHumidity control - The fan will run will run when humidity rises over the pre-set level of 65% RH. Complete with integral timer (15 mins) with manual pull switch.

Low Voltage 12v models

Catalogue No.Type
SL100LVStandard model - for remote switching.
SL100LVAs above supplied with integral pull switch.
SL100VTTimer model - with integral over-run timer (15 mins).
SL100VHTHumidity control - The fan will run will run when humidity rises over the pre-set level of 65% RH. Complete with integral timer (15 mins).


Construction

These fans are moulded in impact resistant high gloss ABS thermoplastics for strength, durability and finish.

Electrical

· 220-230v ~ A.C. 50Hz Single phase consuming 14 watts. These fans are double insulated and do not require an earth. All wiring must comply with current IEE regulations. A double pole isolating switch, having a contact separation of at least 3mm in all poles, must be used with a 3 amp fuse fitted and mounted a minimum of 1.75 metres from the floor and less than 400mm from the ceiling.

Do not install the fan above a heat source. e.g. radiator

Motor

Single phase induction motor with pre-oiled bearings fitted for a long maintenance free life and protected by a thermal fuse.

Guarantee

Two year no quibble guarantee.

Installation

Both 230v and 12v ranges are designed to be wall or ceiling mounted. Kits available on request.

Wall kits comprise a wall sleeve (275mm long) and a gravity grille (white, terracotta, stone, grey or brown).

Ceiling kits comprise 3m 100/150mm flexible ducting and an external fixed grille (colours to suit).

Installation through a wall or ceiling requires a 107mm hole.

Performance

SL100 / SL100LV - extract rate of 90m³/hr, 27 litres per second.

Additional Data

Maximum pressure: 38 p.a. Fan speed: 2400 r.p.m.

Sound volume: 40.0 dB(A) Maximum operating temperature 40ºC.

Protection Rating – IP34

Slimline 100 Range: 230v and 12v

Slimline 100 Range: 230v and 12v
Unit Dimensions & Cut-outs
A150 mm
B150 mm
Ø100 mm
C108 mm
D12 mm
E12 mm
Wall Hole107mm
Ceiling Hole107mm


Back to the top

< < Previous page
pdfDownload & print PDF page
Call me back
print this HTML page

Ferrob Ltd.


Ferrob Ltd.
Regency House, Kingsclere Park, Kingsclere, Newbury, Berks. RG20 4SW
Tel: 01635 299266 Fax: 01635 299277
Email: sales@ferrob.co.uk

Ferrob Ltd.
Click here to go to our accreditations page, where you can download backup documentation

Click here to go to our accreditations page, where you can download backup documentation

Powered by Multiplex Internet Services Last updated 19 October 2007 S