Whole House Ventilation Units - Multivent The Whole House Ventilation unit - Multivent - is a stylish and compact unit that provides a highly efficient and low cost form of continuous and controlled extraction of air from a domestic environment from a single unit.

Its adaptability enables the system to be suitable for common house layouts and can be used on up to five rooms.

The system prevents the need for multiple fans in different rooms and reduces, to one, the number of external outlets required.

The units are supplied in 2 models - manual 2-speed switching and automatic integral humidity sensor. The automatic version runs continuously on slow speed and when the sensor detects a level of humidity above the switch-on point (65% RH), the unit is switched to fast speed.

Once the level has fallen below the pre-set level, the unit will revert to running on trickle speed.

The kit comprises:

1no 6m lengths of 125mm flexible ducting, 2no 3m lengths of 80mm flexible ducting, 1no 125mm ceiling grille, 2no 80mm ceiling grilles, 1no 125mm fixed external grille (terracotta)

Extract rate 370 m³/hr, 103 litres/ sec
Low running costs
British made
2 year no quibble guarantee
Meets Building Regulations 2006
Adaptable for different installations
2-speed operation as standard
Easy to install
Quiet in operation
Multiple connections
One external outlet
CE Mark

Technical Data

Catalogue No.Type
CD125MRVcomplete with 2-speed Manual switch (slow - fast).
CD125MRV-HHumidity control - continuous trickle speed and will run in fast speed when humidity rises over the pre-set level of 65% RH.


Construction

These units are made of strong and durable self-extinguishing plastic for strength, durability and finish.

Electrical

220-230v ~ A.C. 50Hz Single phase consuming 90 watts when on fast speed and 27 watts on slow continuous speed. These units require an earth. All wiring must comply with current IEE regulations. A double pole isolating switch, having a contact separation of at least 3mm in all poles, must be used with a 3 amp fuse fitted.

Motor

Single phase two-speed induction motor with pre-oiled ball-bearings for a long maintenance free life and protected by a thermal fuse.

Guarantee

Two year no quibble guarantee.

Installation

The units are designed to be loft mounted. The extract grilles are generally ceiling mounted with the 80mm grilles used in the bathroom, toilet or en-suite and the 125mm grille from the kitchen.

A simple regulator controls the flow of air from the kitchen.

Full installation and operating instructions are provided with each unit.

Performance

CD125MRV / CD125MRV-H - 58 litres/sec on slow speed and 103 l/s on fast.

Additional Data

Maximum pressure: see table below.

Sound volume - full speed: 25.0 dB(A)

Maximum operating temperature 40ºC.

CD125MRV / CD125MRV-H

SPECIFICATION
CodeDescription Extract PerformancePowerWeight
Multi Room Extract Kitl/sm³/hrcfmWKg
CD125MRVTwo speed operationLow Speed58210122272.4
High Speed103370216902.4
Electricity supply 220-230V ~ 50Hz

Back to the top

< < Previous page
pdfDownload & print PDF page
Call me back
print this HTML page

Ferrob Ltd.


Ferrob Ltd.
Regency House, Kingsclere Park, Kingsclere, Newbury, Berks. RG20 4SW
Tel: 01635 299266 Fax: 01635 299277
Email: sales@ferrob.co.uk

Ferrob Ltd.
Click here to go to our accreditations page, where you can download backup documentation

Click here to go to our accreditations page, where you can download backup documentation

Powered by Multiplex Internet Services Last updated 19 October 2007 S