Open Flue Spillage Prevention Fan
WW150AXSG: 230v

pdf Download & print PDF page

WW150AXSG: 230vThe WW150AXSG kitchen fan comprises quiet, efficient, axial flow fans for wall, ceiling or window mounting. Designed for easy installation, attractively styled in high gloss ABS thermoplastics for modern appearance and ease of cleaning and incorporating the latest technology and design. The units have silently operating electric shutters controlled by a well proven thermo-electric activator. These shutters are designed to eliminate back-draught.

The WW150AXSG is ideally suited where gas spillage may occur.

IMPORTANT
When this unit is installed in the same room as an open flued appliance,
IT MUST ONLY be set on a maximum extract rate of 20 ltrs/sec

Adjustable extract rate 20- 65 litres per second
Fans can be wall or window mounted
British made
Designed to exceed the 2006 Building Regulations on Ventilation (F1)
Tested to comply with HD280/BS3456 Part 102:342 1988
2 year no quibble guarantee
CE Mark

Technical Data

Construction

These fans are moulded in impact resistant high gloss ABS thermoplastics for strength, durability and finish

Electrical

220-230v ~ A.C. 50Hz Single phase consuming 20 watts. These fans are double insulated and do not require an earth. All wiring must comply with current IEE regulations. A double pole isolating switch, having a contact separation of at least 3mm in all poles, must be used with a 3 amp fuse fitted. The fan should be mounted a minimum of 1.75 metres from the floor and less than 400mm from the ceiling.

Do not install the fan above a heat source. e.g. radiator, cooker.

Motor

Single phase induction motor with pre-oiled bearings fitted for a long maintenance free life and protected by a thermal fuse.

Guarantee

Two year no quibble guarantee.

Installation
Designed to be wall or window mounted. Kits available on request.
Wall kits comprise a wall sleeve (275mm long) and a gravity grille (white, terracotta, stone, grey or brown)
Window kits comprise an external white gravity grille and internal fixing plate.
Installation through a wall requires a 162mm hole, through a window a 185mm hole.
Performance

WW150AXSG - extract rate of 20 – 65 litres per second.

Additional Data
Maximum pressure: 50 p.a. Fan speed: 2400 r.p.m.
Sound volume: 38.0 dB(A) Maximum operating temperature 40ºC.
Protection Rating: - IPx4

Mains Voltage models

Sound volume:

38.0 dB(A)
Voltage: 230v AC
Frequency: 50 Hz
Wattage: 20W
Max. Temp: 40ºC
Weight: 1.11kg
Max Pressure: 50pa
Diameter of hole:
Window 185 mm
Wall 162 mm
Glass thickness: Up to 30mm


A

220
B 205
C 155
D 50
E 48

IMPORTANT
When this unit is installed in the same room as an open flued appliance,
IT MUST ONLY be set on a maximum extract rate of 20 ltrs/sec

Back to the top

< < Previous page
pdfDownload & print PDF page
Call me back
print this HTML page

Ferrob Ltd.


Ferrob Ltd.
Regency House, Kingsclere Park, Kingsclere, Newbury, Berks. RG20 4SW
Tel: 01635 299266 Fax: 01635 299277
Email: sales@ferrob.co.uk

Ferrob Ltd.
Click here to go to our accreditations page, where you can download backup documentation

Click here to go to our accreditations page, where you can download backup documentation

Powered by Multiplex Internet Services Last updated 19 October 2007 S