Standard Assessment Procedure – Appendix Q Decentralised MEV Product Data 16/02/2011

SAP Appendix Q Test Results
Decentralised mechanical exhaust ventilation system
packages used in a single dwelling – rigid ductwork

pdf Download & print PDF page

Brand NameFerrob
ModelInfinity 100
Model Qualifier (if applicable)
Current Manufacturer and Contact DetailsNameFerrob Ltd
AddressRegency House
Kingsclere Park
Kingsclere
Newbury
Berks
RG20 4SW
Telephone01635 296 716
Websitewww.ferrob.co.uk
Original Manufacturer (if different)
First Year of Manufacture2011
Last Year of Manufacture
Testing BodyBRE
Date of test08/02/11
Serial Number of Product TestedINF100_00001
Ductwork Type and Size100mm diameter rigid plastic & 100mm rectangular rigid plastic or larger

Results for SAP calculations (at minimum flow rate condition)

Table Q1 – Systems with rigid ductwork installation only

These results are only applicable for SAP Appendix Q if the whole system is installed with rigid ductwork throughout. If a combination of flexible and rigid ductwork is specified only results from Table Q3 are applicable

Unit configurationLocationFan speed settingSpecific fan power (W/l/s)
In room
Kitchen
Wet room
In duct
Kitchen
Wet roomMedium0.52
Through wall
Kitchen
Wet roomSlow0.73

These figures are entered into either:

(a) In the case of SAP software amended to SAP 2005 version 9.81 and allowing direct entry of decentralised MEV data, the SAP software, or

(b) In the case of SAP software amended to SAP 2005 version 9.81 not allowing direct entry of decentralised MEV data, the SAP Q Decentralised MEV Calculation Spreadsheet v9.81 for Rigid Ductwork and the results from the spreadsheet into the Special Features part of the SAP 9.81 software, or

(c) In the case of SAP software to SAP 2005 version 9.80 , the SAP Q Decentralised MEV Calculation Spreadsheet v9.80 for Rigid Ductwork and the results from the spreadsheet into the Special Features part of the SAP 9.80 software.

Results for Approved Document F (at minimum flow rate condition)

Table Q2 – Systems with rigid ductwork installation only

Unit configurationLocation Fan speed setting Flow rate (l/s) Flow rate – wind condition (l/s) % reduction of total flow rate (%)
In roomKitchen
-
-
-
-
Wet room
-
-
-
-
InductKitchen
-
-
-
-
Wet room
-
-
-
-
Through wallKitchen
Medium
13.0
>13.0
0
Wet room
Slow
8.9
8.7
2

Back to the top

< < Previous page
pdfDownload & print PDF page
Call me back
print this HTML page

Ferrob Ltd.


Ferrob Ltd.
Regency House, Kingsclere Park, Kingsclere, Newbury, Berks. RG20 4SW
Tel: 01635 299266 Fax: 01635 299277
Email: sales@ferrob.co.uk

Ferrob Ltd.
Click here to go to our accreditations page, where you can download backup documentation

Click here to go to our accreditations page, where you can download backup documentation

Powered by Multiplex Internet Services Last updated 24 August 2010 S